Thermo Scientific?熱電Orion?奧立龍 PerpHecT? ROSS? 複合pH微量電極:8220BNWP
相關(guān)應(yīng)用: pH, Ion Conductivity, & Oxygen Measurement;Thermo Scientific?Orion?PerpHecT?ROSS?複合pH微量電極可測(cè)量微量樣品。 玻璃桿外面的 PTFE 防護(hù)套使其較常規(guī) pH 微量電極更為持久耐用,並可用於 384 孔板或樣品中測(cè)量 pH 和溫度。
描述 | Combination pH Micro Electrode |
蓋子直徑(公制) | 3 mm |
跨度漂移 | Less than 0.002 pH units/day |
電極 | Glass double junction; Refillable |
長(zhǎng)度(公制) | 155 mm |
線纜長(zhǎng)度(公制) | 1 m |
Z小浸沒(méi)部分 | 4.5mm |
儲(chǔ)存要求 | To ensure a quick response and free-flowing liquid junction the sensing element and reference junction must not be allowed to dry out. Short-term Storage (up to one week): Soak electrode in ROSS pH Electrode Storage Solution, Orion 810001 or use pH Electrode Storage Solution, Orion 910001. To minimize the chance of breakage the 8220BNWP should be attached to an electrode stand and suspended in a beaker that contains pH electrode storage solution. The electrode should not touch the sides or bottom of the beaker. Long-term Storage (more than one week): The reference chamber should be filled and the filling hole securely covered. Cover the sensing element and reference Junction with the protective cap/sleeve containing a few drops of storage solution. Before returning the electrode to use, prepare it as a new electrode. |
Z佳工作溫度(公制) | 0°C to 100°C |
接頭類型 | BNC Waterproof |
接合 | Glass Double |
材料 | Glass |
Unit Size | Each |
含:1m 電纜;需要:pH測(cè)量?jī)x;電極;塑膠或玻璃燒杯;磁力攪拌器;需要的溶液;兩種pH緩衝液:pH7和pH4或10;ROSS內(nèi)填充溶液: 3M KCl;Orion目錄,訂貨號(hào) 810007;相容:Orion? PerpHecT? 儀錶;
Thermo Scientific?熱電Orion?奧立龍 PerpHecT? ROSS? 複合pH微量電極:8220BNWP
相關(guān)應(yīng)用: pH, Ion Conductivity, & Oxygen Measurement;Thermo Scientific?Orion?PerpHecT?ROSS?複合pH微量電極可測(cè)量微量樣品。 玻璃桿外面的 PTFE 防護(hù)套使其較常規(guī) pH 微量電極更為持久耐用,並可用於 384 孔板或樣品中測(cè)量 pH 和溫度。
描述 | Combination pH Micro Electrode |
蓋子直徑(公制) | 3 mm |
跨度漂移 | Less than 0.002 pH units/day |
電極 | Glass double junction; Refillable |
長(zhǎng)度(公制) | 155 mm |
線纜長(zhǎng)度(公制) | 1 m |
Z小浸沒(méi)部分 | 4.5mm |
儲(chǔ)存要求 | To ensure a quick response and free-flowing liquid junction the sensing element and reference junction must not be allowed to dry out. Short-term Storage (up to one week): Soak electrode in ROSS pH Electrode Storage Solution, Orion 810001 or use pH Electrode Storage Solution, Orion 910001. To minimize the chance of breakage the 8220BNWP should be attached to an electrode stand and suspended in a beaker that contains pH electrode storage solution. The electrode should not touch the sides or bottom of the beaker. Long-term Storage (more than one week): The reference chamber should be filled and the filling hole securely covered. Cover the sensing element and reference Junction with the protective cap/sleeve containing a few drops of storage solution. Before returning the electrode to use, prepare it as a new electrode. |
Z佳工作溫度(公制) | 0°C to 100°C |
接頭類型 | BNC Waterproof |
接合 | Glass Double |
材料 | Glass |
Unit Size | Each |
含:1m 電纜;需要:pH測(cè)量?jī)x;電極;塑膠或玻璃燒杯;磁力攪拌器;需要的溶液;兩種pH緩衝液:pH7和pH4或10;ROSS內(nèi)填充溶液: 3M KCl;Orion目錄,訂貨號(hào) 810007;相容:Orion? PerpHecT? 儀錶;